{"product_id":"v-tuf-maxi-80l-h-class-240v-3500w-industrial-dust-extraction-vacuum-cleaner-32ft-high-level-cleaning-kit-pipe-cleaning-tools","title":"V-TUF MAXi - 80L H-Class 240v 3500w Industrial Dust Extraction Vacuum Cleaner - 32Ft High Level Cleaning Kit \u0026 Pipe Cleaning Tools","description":"\u003cp\u003e\u003cstrong\u003eA high-capacity H-Class vacuum with 10-metre high-level cleaning kit — for hazardous dust extraction in ceiling voids, pipe runs and elevated areas.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MAXi 80L H-Class 240V 3500W (SKU: MAXIH24080LKIT2)\u003c\/strong\u003e is a heavy-duty 80-litre H-Class vacuum with a 10-metre high-level cleaning kit and pipe cleaning heads for hazardous dust extraction in hard-to-reach elevated locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Specialist contractors, remediation operators and industrial sites requiring H-Class extraction with extended high-level reach — ceiling voids, ventilation ducts, pipe runs, roof spaces and elevated structural surfaces where standard-length hose kits are insufficient.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA 99.995% | Capacity: 80L stainless steel tank | Power: 3500W, 240V\u003c\/li\u003e\n\u003cli\u003eHigh-level kit: 10 metres (32ft) with pipe cleaning heads\u003c\/li\u003e\n\u003cli\u003eAirflow monitor — alerts when filter is blocked, bag is full, or hose is restricted\u003c\/li\u003e\n\u003cli\u003eApproved for Dust Class H\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAXi 80L H-Class 240V machine | 10m high-level cleaning kit | Pipe cleaning heads | H14 HEPA filter | 5m flexible yellow vacuum hose\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class operation — full decontamination procedure required during bag and filter changes. The high-level kit is for dry dust extraction only and must not be used for liquid pickup.\u003c\/p\u003e\n\u003cp\u003e1-year manufacturer warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction and refurbishment — ceiling voids and structural cavities\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing — roof spaces and pre-2000 building fabric\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare and NHS estates — ventilation duct cleaning and elevated surfaces\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing — pipe runs and elevated machinery housings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine and shipyard refit — bilge voids and elevated structural areas\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class mandatory for all vacuum work involving asbestos dust, including ceiling voids and roof spaces of pre-2000 buildings. M-Class not permitted under any CAR 2012 work category.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould, asbestos, lead paint, MDF dust and carcinogenic process dusts all require H-Class containment. Working at height does not reduce the COSHH obligation.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — H-Class required wherever the COSHH assessment identifies hazardous dust, regardless of working height or access method.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — RCS WEL 0.1 mg\/m3. H-Class required in enclosed environments including ceiling voids and duct systems where dust concentrations build rapidly.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class mandatory for Type C and D works in NHS hospitals including above-ceiling work in clinical areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on the building material\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/pages\/h-class-dust-extraction\"\u003eH-Class dust extraction — full guidance\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine\u003c\/a\u003e | \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides\u003c\/a\u003e | 01522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56396624232788,"sku":"MAXIH24080LKIT2","price":1291.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MAXIH80240KIT2_1_8ce47713-444b-4655-99d0-8073b4c4a91f.png?v=1783587991","url":"https:\/\/vtuf.myshopify.com\/products\/v-tuf-maxi-80l-h-class-240v-3500w-industrial-dust-extraction-vacuum-cleaner-32ft-high-level-cleaning-kit-pipe-cleaning-tools","provider":"V-TUF","version":"1.0","type":"link"}