{"product_id":"vtuf-grindex1300lps-3300w-110v","title":"V-TUF GRINDEX1300LPS H-Class Industrial Dust Extractor - 3300W, 450m³\/h - 110V","description":"\u003cp\u003e\u003cstrong\u003eCertified H-Class protection built for the toughest industrial dust extraction jobs.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eV-TUF GRINDEX1300LPS-110\u003c\/strong\u003e is a high-capacity, three-motor H-Class industrial dust extractor with automatic reverse-flow filter cleaning, built for continuous operation with surface preparation machinery.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Contractors and industrial operators running grinders, scarifiers, sanders and shot blasters who need certified H-Class extraction for very fine, hazardous dust over extended shifts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePower: 3300W total | Voltage: 110V, 60Hz\u003c\/li\u003e\n\u003cli\u003eMotor: 3× by-pass motors\u003c\/li\u003e\n\u003cli\u003eAirflow: 450 m³\/h | Max vacuum (depression): 200 mBar\u003c\/li\u003e\n\u003cli\u003eTangential suction inlet\u003c\/li\u003e\n\u003cli\u003ePrimary filter: HEPA + PTFE, 3× cartridge, 20,500cm² filtering surface\u003c\/li\u003e\n\u003cli\u003eFilter cleaning: Automatic, continuous-suction reverse-flow system\u003c\/li\u003e\n\u003cli\u003eCollection system: Longopac® 22m continuous bag, optional 100L tank\u003c\/li\u003e\n\u003cli\u003eFilter chamber diameter: 460mm\u003c\/li\u003e\n\u003cli\u003eSound pressure level: 78dB\u003c\/li\u003e\n\u003cli\u003eClass: H-Class standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eImportant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNot suitable for vacuuming liquids.\u003c\/li\u003e\n\u003cli\u003eCheck the machine is connected to a power source matching the voltage shown on the rating plate before use.\u003c\/li\u003e\n\u003cli\u003eDo not use in confined spaces without adequate fresh air, and never cover the machine during use.\u003c\/li\u003e\n\u003cli\u003eNever vacuum explosive, incendiary or corrosive substances or vapours; only vacuum damped cigarette butts.\u003c\/li\u003e\n\u003cli\u003eCheck the cartridge filter is fitted and in good condition before vacuuming toxic substances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003cbr\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere This Machine Is Used\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/manufacturing\"\u003eManufacturing \u0026amp; Engineering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/facilities-management\"\u003eFacilities Management\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/cleaning-trade\"\u003eCleaning Trade\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eLegislation That Applies\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCOSHH Regulations 2002:\u003c\/strong\u003e As a dust-generating machine, the GRINDEX1300LPS supports compliance with the Control of Substances Hazardous to Health Regulations, helping control exposure to hazardous fine dust at source. \u003ca href=\"\/pages\/coshh-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCDM 2015:\u003c\/strong\u003e On construction sites, the Construction (Design and Management) Regulations 2015 place duties on contractors to manage dust risk — H-Class extraction is a recognised control measure. \u003ca href=\"\/pages\/cdm-2015\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHSE EH40 Workplace Exposure Limits:\u003c\/strong\u003e H-Class extraction helps operators stay within HSE EH40 workplace exposure limits for hazardous dust and substances. \u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eControl of Asbestos Regulations 2012:\u003c\/strong\u003e As an H-Class machine, the GRINDEX1300LPS meets the extraction standard required under CAR 2012 for work involving asbestos-containing materials. \u003ca href=\"\/pages\/asbestos-regulations\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePUWER 1998:\u003c\/strong\u003e Suitable for use as compliant work equipment under the Provision and Use of Work Equipment Regulations 1998 in commercial and industrial settings. \u003ca href=\"\/pages\/puwer\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eICRA:\u003c\/strong\u003e Where used inside healthcare or hospital environments, H-Class extraction supports compliance with Infection Control Risk Assessment requirements. \u003ca href=\"\/pages\/icra\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAwaab's Law:\u003c\/strong\u003e Where used for mould remediation in social housing, H-Class extraction is a recognised control measure under Awaab's Law. \u003ca href=\"\/pages\/awaabs-law\"\u003eLearn more\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFurther Reading\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/silica-dust-construction-sites-regulations\"\u003eSilica dust on construction sites: what the regulations actually require\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-construction-car-2012-pre-2000-buildings\"\u003eAsbestos in construction: what CAR 2012 requires for contractors working in pre-2000 buildings\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction: what contractors working inside hospitals need to know\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eSupport\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHaving an issue? Use our \u003ca href=\"\/pages\/grindex1300lps-troubleshooting\"\u003eGRINDEX1300LPS Troubleshooting Guide\u003c\/a\u003e to diagnose and fix common faults. Need a filter or collection bag? See \u003ca href=\"\/pages\/grindex1300lps-spare-parts\"\u003eGRINDEX1300LPS Spare Parts\u003c\/a\u003e (pricing being finalised — contact us directly to order). For anything else, visit the \u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eV-TUF Support Hub\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eEmail: enquiries@v-tuf.com | Phone: +44 (0)1522 787978\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"Default Title","offer_id":56385125810516,"sku":"GRINDEX1300LPS-110","price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/GRINDEX1300LPS_1.jpg?v=1783504545","url":"https:\/\/vtuf.myshopify.com\/products\/vtuf-grindex1300lps-3300w-110v","provider":"V-TUF","version":"1.0","type":"link"}