{"product_id":"vtuf-maxi-50l-h-class-industrial-dust-extraction-vacuum-cleaner-110v-1750w","title":"V-TUF MAXi 50L H-Class Industrial Dust Extraction Vacuum Cleaner - 110V (Transformer Required)","description":"\u003cp\u003e\u003cstrong\u003eA high-capacity H-Class vacuum — ideal for large remediation and heavy-duty dust extraction.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eV-TUF MAXi 50L H-Class 110V 1750W Industrial Dust Extraction Vacuum Cleaner (MAXIH110)\u003c\/strong\u003e is a large-capacity 50-litre H-Class industrial vacuum on 110V site-safe supply for the highest level of dust protection against carcinogens, asbestos fibres, and hazardous respirable particles. For 240V see MAXIH240. For 80L see MAXI80H. 110V requires site transformer.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFor:\u003c\/strong\u003e Asbestos removal contractors, lead paint remediation teams, and refurbishment trades on 110V site supply requiring large-capacity H-Class extraction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFiltration: H-Class H14 HEPA | Power: 1750W, 110V | Tank: 50 litres | Dry only\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWhat's included:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMAXi 50L 110V machine | Hose, wand, and floor tool set | H14 HEPA filter and dust bags\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e H-Class PPE required during bag changes. For asbestos work follow BS 8520-3:2009.\u003c\/p\u003e\u003cp\u003e1-year manufacturer's warranty. Genuine V-TUF, supplied from our Lincoln warehouse.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhere this machine is used\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/construction\"\u003eConstruction \u0026amp; refurbishment\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/social-housing\"\u003eSocial housing maintenance\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/healthcare\"\u003eHealthcare \u0026amp; NHS estates\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/marine\"\u003eMarine \u0026amp; shipyard refit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/motorsport-valley\"\u003eMotorsport Valley \u0026amp; composites\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLegislation that applies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/asbestos-regulations\"\u003eControl of Asbestos Regulations 2012 (CAR 2012)\u003c\/a\u003e — H-Class mandatory for all vacuum work involving asbestos dust. M-Class not permitted under any CAR 2012 work category.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/icra\"\u003eInfection Control Risk Assessment (ICRA)\u003c\/a\u003e — H-Class mandatory for Type C and D works in NHS hospitals.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/coshh-regulations\"\u003eCOSHH Regulations 2002\u003c\/a\u003e — Mould, asbestos, carbon fibre and lead paint require H-Class containment.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/cdm-2015\"\u003eCDM 2015\u003c\/a\u003e — H-Class required wherever COSHH assessment identifies hazardous dust.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/electricity-at-work-regulations\"\u003eElectricity at Work Regulations 1989\u003c\/a\u003e — 110V CTE mandated on UK construction sites.\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/pages\/hse-eh40-workplace-exposure-limits\"\u003eHSE EH40\u003c\/a\u003e — RCS WEL 0.1 mg\/m³. H-Class required in enclosed environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFurther reading\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/asbestos-car-2012-construction-contractors\"\u003eAsbestos in construction: what CAR 2012 requires →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/icra-healthcare-construction-h-class-extraction\"\u003eICRA in healthcare construction →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"\/blogs\/compliance-centre\/m-class-or-h-class-dust-extractor-building-material-guide\"\u003eM-Class or H-Class: why it depends on what the building is made of →\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupport:\u003c\/strong\u003e \u003ca href=\"\/pages\/all-machines-spare-parts\"\u003eFind parts for your machine →\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"\/pages\/v-tuf-support-hub\"\u003eTroubleshooting guides →\u003c\/a\u003e\u003cbr\u003eOr call our Lincoln service team on 01522 787978.\u003c\/p\u003e","brand":"V-TUF","offers":[{"title":"110v","offer_id":55798376857940,"sku":"MAXIH110-50L","price":799.99,"currency_code":"GBP","in_stock":true},{"title":"240v","offer_id":55983487746388,"sku":"MAXIH240-50L","price":799.99,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/6208\/6740\/files\/MAXIH110-50L_1S_82aa6e43-458b-4138-94b2-b80ac75f89fd.jpg?v=1780486190","url":"https:\/\/vtuf.myshopify.com\/products\/vtuf-maxi-50l-h-class-industrial-dust-extraction-vacuum-cleaner-110v-1750w","provider":"V-TUF","version":"1.0","type":"link"}