Construction & Site Work Dust Extractors — Northampton

Construction & site work — Northampton

V-TUF supplies M-Class and H-Class dust extraction to construction sites across Northampton and West Northamptonshire. The Northampton Waterside Enterprise Zone, DIRFT III at Daventry, University of Northampton Waterside Campus expansion and sustained residential growth across the district all generate sustained CDM-compliant dust extraction demand. Northampton General Hospital NHS Trust operates NGH on Billing Road with active capital works programmes requiring ICRA-compliant H-Class extraction in clinical areas.

V-TUF regularly supplies contractors working across Northampton, DIRFT, Wootton, Collingtree and surrounding West Northamptonshire construction sites.

← Back to V-TUF Northampton hub


Recommended machines

V-TUF MINI HSV — M-Class dust extractor, compact

H13 HEPA, 99.9% filtration. Suited to first and second fix across the Waterside and Collingtree residential programmes. Available in 110V and 240V. SKU MINIHSV110 / MINIHSV240.

View MINI HSV M-Class extractor →

V-TUF MIGHTY HSV — 21L M-Class dust extractor

21-litre wet/dry, autostart power take-off. Sustained M-Class specification for Northampton's major construction programmes including DIRFT III and Waterside. SKU MIGHTYHSV110 / MIGHTYHSV240.

View 21L M-Class dust extractor →

V-TUF MIDI H-Class — 21L H-Class dust extractor

H14 HEPA at 99.995%. Mandatory for silica-generating operations, for all construction within the NGH estate under ICRA protocols, and for carbon fibre composite dust generated during engineering and manufacturing facility works across the Motorsport Valley corridor around Silverstone. SKU MIDIH110 / MIDIH240.

View 21L H-Class dust extractor →


Typical use case — DIRFT III logistics facility construction

A principal contractor building large-span logistics facilities at DIRFT III runs MIGHTY HSV M-Class units (110V, autostart) across all cutting, grinding and structural operations. MIDI H-Class units specified for concrete cutting and masonry phases. Contractor trade account — next-day delivery to NN6 postcode.


Compliance notes for Northampton construction sites

  • CDM 2015 Regulation 15(2) — principal contractors must demonstrate dust control planning in the pre-construction health and safety plan.
  • COSHH 2002 — RCS WEL 0.1mg/m³ over an 8-hour TWA. H-Class required for silica-generating operations.
  • Control of Asbestos Regulations 2012 — H-Class extraction mandatory for any work near or involving asbestos-containing materials in pre-2000 Northampton buildings. Town centre refurbishment and social housing regeneration across Northampton involve pre-2000 commercial and residential stock where ACMs in textured coatings, floor tiles and pipe lagging are a documented risk.
  • ICRA — Northampton General Hospital NHS Trust — ICRA required for all works inside NGH at Billing Road. H-Class mandatory for Type C and D work in clinical areas.
  • Carbon fibre and advanced composites — Motorsport Valley corridor — construction and maintenance works on engineering and motorsport supply chain facilities around Silverstone generate carbon fibre composite dust requiring H-Class extraction under COSHH 2002.
  • 110V on site — all V-TUF M-Class and H-Class extractors available in 110V CTE.

Further reading on dust control, COSHH compliance and extraction class selection for construction materials used across Northampton and the Motorsport Valley corridor:

CDM 2015 → COSHH Regulations 2002 → Control of Asbestos Regulations 2012 → ICRA → Electricity at Work Regulations 1989 →


Choosing the right dust extractor for your Northampton site

  • General fit-out, refurbishment and residential new-build: MINI HSV or MIGHTY HSV (M-Class)
  • Silica-generating work — cutting, grinding, drilling masonry or concrete: MIDI H-Class (H14 HEPA, 99.995%)
  • Pre-2000 building refurbishment or demolition with suspected ACMs: MIDI H-Class mandatory — see Control of Asbestos Regulations 2012 →
  • Carbon fibre composite dust on Motorsport Valley engineering sites: MIDI H-Class — H-Class legal minimum under COSHH 2002
  • Works inside NGH under ICRA: MIDI H-Class mandatory for Type C and D clinical areas
  • 110V site requirement: All three machines available in 110V CTE

Contractor account terms — next-day delivery to Northampton NN postcodes. Telephone 01522 787978.


Frequently asked questions

What extraction is required for construction inside Northampton General Hospital?

All construction and maintenance inside NGH at Billing Road requires an ICRA before starting. For Type C and D work in clinical areas H-Class extraction is mandatory. The MIDI H-Class (MIDIH110 / MIDIH240) with sealed filtration and HEPA-certified disposal bags is the correct specification.

Is H-Class required for engineering and maintenance works on Motorsport Valley facilities near Silverstone?

Yes, where carbon fibre composite materials are involved. Construction and maintenance on engineering facilities across the Silverstone and A43 corridor can generate carbon fibre dust during cutting, drilling and sanding. Carbon fibre dust requires H-Class extraction under COSHH 2002.

For residential environments where damp, mould or indoor air quality issues are present — including social housing and void properties across Northampton and West Northamptonshire — see Condensation mould vs penetrating damp: how to tell the difference → and Black mould on walls: what it is and what to do →


Servicing, spares and ongoing support

All V-TUF M-Class and H-Class extractors supported with UK-based spare parts and full servicing. HEPA cartridges and certified disposal bags held for ICRA-compliant use across the NGH estate.

V-TUF Support Hub → Spare parts for all machines →


Dust generated by cutting, grinding and drilling on Northampton construction sites must be controlled at source under COSHH 2002. See COSHH Regulations guidance → and M-Class or H-Class extraction guidance → for a full breakdown of compliant dust control requirements.


Back to V-TUF Northampton hub →