Construction & Site Work Dust Extractors — Swindon

Construction & site work — Swindon

V-TUF supplies M-Class and H-Class dust extraction to construction sites across Swindon and Wiltshire. The Kimmerfields regeneration, Central Swindon North masterplan, Panattoni Swindon and Symmetry Park Swindon logistics parks on the former Honda South Marston site, New College Swindon campus redevelopment, and the sustained residential growth programme across Wichelstowe, Tadpole Garden Village and the wider Swindon growth area all generate sustained CDM-compliant dust extraction demand. Great Western Hospitals NHS Foundation Trust operates the Great Western Hospital on Marlborough Road with active capital works requiring ICRA-compliant H-Class extraction in clinical areas.

V-TUF regularly supplies contractors working across Swindon town centre, South Marston, Kimmerfields and surrounding Wiltshire construction sites.

← Back to V-TUF Swindon hub


Recommended machines

V-TUF MINI HSV — M-Class dust extractor, compact

110V or 240V, H13 HEPA, 99.9% filtration. Available in 110V and 240V. SKU MINIHSV110 / MINIHSV240.

View MINI HSV M-Class extractor →

V-TUF MIGHTY HSV — 21L M-Class dust extractor

110V or 240V, H13 HEPA, 99.9% filtration, 21-litre wet/dry, autostart power take-off. Sustained M-Class specification for Swindon's major construction and logistics park build programmes. SKU MIGHTYHSV110 / MIGHTYHSV240.

View 21L M-Class dust extractor →

V-TUF MIDI H-Class — 21L H-Class dust extractor

110V or 240V, H14 HEPA, 99.995% filtration, 21-litre, sealed filtration. Mandatory for silica-generating operations and for all construction within the GWH estate at Marlborough Road under ICRA protocols. SKU MIDIH110 / MIDIH240.

View 21L H-Class dust extractor →


Typical use case — Panattoni Swindon logistics park construction

A principal contractor building large-span logistics facilities at Panattoni Swindon's South Marston site runs MIGHTY HSV M-Class units (110V, autostart) across all cutting, grinding and structural operations. MIDI H-Class units specified for concrete cutting and masonry phases. Contractor trade account — next-day delivery to SN3 postcode.


Compliance notes for Swindon construction sites

  • CDM 2015 Regulation 15(2) — principal contractors must demonstrate dust control planning in the pre-construction health and safety plan.
  • COSHH 2002 — RCS WEL 0.1mg/m³ over an 8-hour TWA. H-Class required for silica-generating operations.
  • Control of Asbestos Regulations 2012 — H-Class extraction mandatory for any work near or involving asbestos-containing materials in pre-2000 Swindon buildings. Refurbishment of the former Honda South Marston manufacturing site and Swindon's pre-2000 commercial and social housing stock involves buildings where ACMs in insulation, pipe lagging and textured coatings are a documented risk.
  • ICRA — Great Western Hospitals NHS FT — ICRA required for all works inside GWH at Marlborough Road. H-Class mandatory for Type C and D work in clinical areas.
  • 110V on site — all V-TUF M-Class and H-Class extractors available in 110V CTE.

Further reading on dust control, COSHH compliance and extraction class selection for construction materials used across Swindon sites:

CDM 2015 → COSHH Regulations 2002 → Control of Asbestos Regulations 2012 → ICRA → Electricity at Work Regulations 1989 →


Choosing the right dust extractor for your Swindon site

  • General fit-out, refurbishment and residential new-build: MINI HSV or MIGHTY HSV (M-Class)
  • Silica-generating work — cutting, grinding, drilling masonry or concrete: MIDI H-Class (H14 HEPA, 99.995%)
  • Pre-2000 building refurbishment or demolition with suspected ACMs (including former Honda South Marston site): MIDI H-Class mandatory — see Control of Asbestos Regulations 2012 →
  • Works inside GWH under ICRA: MIDI H-Class mandatory for Type C and D clinical areas
  • 110V site requirement: All three machines available in 110V CTE

Contractor account terms — next-day delivery to Swindon SN postcodes. Telephone 01522 787978.


Frequently asked questions

What extraction is required for construction inside the Great Western Hospital?

All construction and maintenance inside GWH at Marlborough Road requires an ICRA before starting. For Type C and D work in clinical areas H-Class extraction is mandatory. The MIDI H-Class (MIDIH110 / MIDIH240) with sealed filtration and HEPA-certified disposal bags is the correct specification.

Is M-Class or H-Class required on the Panattoni Swindon logistics park construction?

M-Class is the minimum for general construction dust across the logistics facility builds. H-Class is required wherever silica is generated — concrete cutting, grinding or drilling of masonry. On large-span concrete frame construction of the scale at Panattoni and Symmetry Park, H-Class should be specified in the CDM dust management plan for all masonry and concrete cutting phases.

For residential environments where damp, mould or indoor air quality issues are present — including social housing and void properties across Swindon and Wiltshire — see Condensation mould vs penetrating damp: how to tell the difference → and Black mould on walls: what it is and what to do →


Servicing, spares and ongoing support

All V-TUF M-Class and H-Class extractors supported with UK-based spare parts and full servicing. HEPA cartridges and certified disposal bags held for ICRA-compliant use across the Great Western Hospital estate.

V-TUF Support Hub → Spare parts for all machines →


Dust generated by cutting, grinding and drilling on Swindon construction sites must be controlled at source under COSHH 2002. See COSHH Regulations guidance → and M-Class or H-Class extraction guidance → for a full breakdown of compliant dust control requirements.


Back to V-TUF Swindon hub →