tufJET1 and tufJET2 Troubleshooting
tufJET1 and tufJET2 · Support
Troubleshoot Your tufJET
Covers the full tufJET range — tufJET1 110V (100 Bar) and 240V (130 Bar), and tufJET2 110V and 240V with stainless frame. Pick the problem below and we’ll walk you through the fix.
tufJET1 and tufJET2 — same machine, same fixes
The tufJET2 is the tufJET1 with a stainless steel frame. The pump, motor, gun, lance, hose, nozzles and all service parts are identical. Every issue and fix on this page applies equally to both models.
1
What’s Going Wrong?
5 Things To Check Before Anything Else
1. Water on firstAlways turn the water supply on and squeeze the trigger to bleed air before powering up. Never run dry.
2. Power supply110V machine on a 110V transformer; 240V machine on a 13A socket. Check the breaker has not tripped.
3. No extension cables240V on a long thin extension causes voltage drop and start failures. Plug direct or use a heavy-duty lead.
4. Inlet filterUnscrew the inlet, pull the strainer, rinse it clear. Blocked filters starve the pump and kill pressure.